About Me

header ads

Digital Storage Oscilloscope Hantek DSO5062B

Hantek DSO5062B 60MHz Digital Storage Oscilloscope

Features :
  • 60MHz bandwidths
  • 1GSa/s Real Time sample rate
  • Large ( 7.0-inch) color display, WVGA(800×480)
  • Record length up to 1M
  • Trigger mode: edge/pulse width/line selectable video/slop/overtime etc.
  • USB host and device connectivity, standard
  • Multiple automatic measurements
  • Four math functions, including FFTs standard
  • Provides software for PC real-time analysis

Specification :
  • Model : DSO5062B
  • Bandwidth : 60MHz
  • Real-time Sample Rate : 1GSa/s
  • Equivalent Sample Rate : 25GSa/s
  • Record Length( Sample Points) : Single-channel: Maximum 1M; Dual-channel: Maximum 512K (4K, 16K, 40K optional)
  • SEC/DIV Range : 4nS/div-40S/div (in a 2, 4, 8 sequence)
  • Delay Time Accuracy : 500ps
Vertical
  • A/D Converter : 8-bit resolution, each channel sampled simultaneously
  • VOLTS/DIV Range : 2mVdiv^ 5V/div at input BNC
  • Position Range : ±50V(5V/div) , ±40V(2V/div^ 500mV/div) , 2V(200mV/div^ 50mV/div) ±400mV(20mV/div^ 2m V/div)
  • Bandwidth Limit : 20MHz
  • Rise Time at BNC : d5.8ns
DC Gain Accuracy
  • ± 4% for Sample or Average acquisition mode, 5mV/div to 2mV/div
  • ± 3% for Sample or Average acquisition mode, 5V/div to 10mV/div
Trigger
Trigger Sensitivity (Edge Trigger Type) :
  • DC: CH1/CH2(Typical) 1div from DC to 10MHz; 1.5div from 10MHz to Full
  • EXT Typical 200mV from DC to 40MHz
  • EXT/ 5 Typical 1V from DC to 40MHz
  • AC: Attenuates signals below 10Hz
  • HF Reject: Attenuates signals above 80kHz
  • LF Reject: Attenuates signals below 150kHz
  • Noise Reject: Reduces trigger sensitivity
Trigger Level Range
  • CH1, CH2: ± 8 divisions from center of screen
  • EXT: ± 1.2V EXT/ 5: ± 6V
Trigger Level Accuracy, typical (Accuracy is for signals having rise and fall times e20ns) :
  • CH1, CH2: ± (0.3div× V/div) (within ± 4 divisions from center of screen)
  • EXT: ± (6% of setting + 40mV)
  • EXT/ 5: ± (6% of setting + 200mV)
Hold off Range : 100ns-10s
Trigger Type
  • Edge : Trigger on the rising or falling edge
  • Pulse Width : Trigger (when >,, <, =, `) on a positive or negative slope, Set Time: 20ns–10s
  • Overtime : from the rising or falling edge, Set Time: 20-10s
  • Alternate : Internal trigger on edge, pulse width, video or slope
Measurement
Cursors
  • Manual: The difference between voltage cursors ³ V; the difference between time cursors ³ T; 1/³ T calculated by Hz.
  • Tracing: The voltage and time at a waveform point
Automatic : Pk-Pk, Max, Min, Mean, Cyc RMS, Frequency, Period, Rise Time, Fall Time, Positive Width, Negative Width
Display
  • Type : Right angle 7″ TFT 16-digit color LCD
  • Resolution : 800*480 dots
  • Contrast : 16 gears, with the progress bar to show adjustment
  • Interface : USB host and USB slave
Power Supply
Voltage
  • 100-120VACRMS(±10%) 45Hz to 440Hz CATa
  • 120-240VACRMS(±10%) 45Hz to 66Hz CATa
Power : < 30W
Fuse : 2A, T rating, 250V
Mechanical
  • Size : Length: 313mm Width: 108mm Height: 142mm
  • Weight : 2.08Kg (exclusive of packing and accessories)

Post a Comment